Bubble Cpap

Leading Manufacturer of bubaal cpap machine without compressor and bubble cpap machine with compressor from Ahmedabad.

Bubaal cpap machine Without Compressor

Request Callback

₹ 120000 / Piece Get Latest Price

Product Brochure
SizeMedium
BrandTMS
TypeAuto CPAP
ModelCpap
Pressure Range (cm H2O)3 - 10
PortableYes

Minimum order quantity: 1 Piece

Respiratory System :
Comfortably Provide Hogh Flows0-40 Ltr/Min Of Air/Oxygen Mixtures 21-100% Fio2 to spontaneously breathing patient through the inique optiflow. 
Product Specifications

•       CPAP range (mean): 3 – 10 cmH₂O

•       Operational input flow range is 4 – 15 L/min.

•       An initial range of 6 – 8 L/min is recommended.

•       Gas Leakage @ 60 cmH₂O: <30 mL/min

•       Humidification Output (Invasive Mode)

>33 mg/L from 4 to 15L/min over temp range 20 °C to 26 °C

•       Resistance to flow @ 2.5 L/min Inspiratory Limb: 0.09 ± 0.032 cmH₂O

Expiratory Limb: 0.05 ± 0.022 cmH₂O (including 0.02 cmH₂O measurement uncertainty)

•       Compliance @ 60 cmH₂O:

0.8 ± 0.16 mL/cmH₂O

(including 0.07 mL/cmH₂O measurement uncertainty).

•       Tube minimum internal diameter: Inspiratory: 10.9 mm

Expiratory: 10.0 mm

Bubble Cpap Machine With Compressor

Request Callback

₹ 160000 / Piece Get Latest Price

Product Brochure
SizeMedium
ModelBubble cpap with comressor
Pressure Range (cm H2O)3 - 10

Minimum order quantity: 1 Piece

Respiratory System :
Comfortably Provide Hogh Flows0-40 Ltr/Min Of Air/Oxygen Mixtures 21-100% Fio2 to spontaneously breathing patient through the inique optiflow. 
Product Specifications

•       CPAP range (mean): 3 – 10 cmH₂O

•       Operational input flow range is 4 – 15 L/min.

•       An initial range of 6 – 8 L/min is recommended.

•       Gas Leakage @ 60 cmH₂O: <30 mL/min

•       Humidification Output (Invasive Mode)

>33 mg/L from 4 to 15L/min over temp range 20 °C to 26 °C

•       Resistance to flow @ 2.5 L/min Inspiratory Limb: 0.09 ± 0.032 cmH₂O

Expiratory Limb: 0.05 ± 0.022 cmH₂O (including 0.02 cmH₂O measurement uncertainty)

•       Compliance @ 60 cmH₂O:

0.8 ± 0.16 mL/cmH₂O

(including 0.07 mL/cmH₂O measurement uncertainty).

•       Tube minimum internal diameter: Inspiratory: 10.9 mm

Expiratory: 10.0 mm


X

Contact Us

Trisha Patel (Admin Assistant)
True Meditech Solution
Block-E, Shed No 89, Pushpdeep Industrial Hub And Arcade, B/S City Gold Cinema, Nutan Mill Compound, Saraspur, Ahmedabad
Ahmedabad - 380018, Gujarat, India

Get Directions
Send Email
Share: